The Swedish company SCANIA, based in Södertälje was founded in 1900 in Sweden and is today best known for the heavy trucks over 16 tons. In addition, industrial engines, marine engines and power generation engines were produced. For the construction of generators the engines has to be reliable, durable and a minimun maintenance and repair expenses. SCANIA engines are designed especially compact. Any manintenance work can be performed by a single technician. Thanks to the modern EMS (Engine Management System) the SCANIA engines were regulated extremely precise and can take impresively high load jumps. Thereby the exhaust emissions remain at low levels. SCANIA generator sets can be operated with 100% biodiesel (DIN 12241) besides diesel / heating oil.
|
Diesel Generators - SCANIA | 1.500 rpm | 200 - 550 kVAFor the sound-proof generator sets of Scania powered MSW series extended fuel tanks in base frame (double-walled) were offered optional with a volume from 995 to 2.100 liters depending on the size of the enclosure / genset housing. |
Type | Power | Phases | Amp. | Engine type | ||||
---|---|---|---|---|---|---|---|---|
MSW 255 | 250 kVA | 200 kW | 3~ 400V | 361 A | DC9 65A (10-93) | |||
MSW 280 | 281 kVA | 225 kW | 3~ 400V | 406 A | DC9 65A (10-94) | |||
MSW 300 | 300 kVA | 240 kW | 3~ 400V | 433 A | DC12 59A (10-31A) | |||
MSW 350 | 350 kVA | 280 kW | 3~ 400V | 505 A | DC12 59A (10-32A) | |||
MSW 400 | 400 kVA | 320 kW | 3~ 400V | 577 A | DC12 59A (10-33A) | |||
MSW 455 | 455 kVA | 364 kW | 3~ 400V | 657 A | DC12 59A (10-34A) | |||
MSW 505 | 502 kVA | 402 kW | 3~ 400V | 725 A | DC16 45A (10-30A) | |||
MSW 550 | 550 kVA | 440 kW | 3~ 400V | 794 A | DC16 44A (10-27) |
Rated power at 400/230V, 50 Hz. Fuel consumption at 75% (3/4) PRP load. Speed at 60 Hz: 1,800 rpm.
Available voltage at 50 Hz: 415/240V, 400/230V, 380/220V, 240/120V, 230/115V, 220/110V.
Available voltage at 60 Hz: 480/277V, 460/265V, 440/254V, 240/120V, 230/115V, 220/110V, 208/120V.
Rated Power kVA/kW - PRP Prime Power according to ISO 8528 - maximum available electrical power (at variable load) within the specified maintenance intervals for an unlimited number of hours per year. The average power output may not exceed 80% of PRP power within a period of 24 hours. 10% overload is permitted only temporarily.
Technical data relate to standard reference conditions according to ISO 8528: +25°C, 100 m ALT (1000 mbar), 30% relative humidity. During running-in period of the engine the output increases by approx. 5%. The performance values decrease at higher altitudes, with higher temperatures and higher humidity conformance with DIN ISO 3046.